Cognos SDK -- operation time out when using .NET Framework 2.0 and C#

If you are updating your .NET Framework to 2.0 and using Visual Studio .NET 2005 then it is important to perform proper regression testing on your Cognos SDK application and its C# (c-sharp) code.

 

The default timeout for httpwebrequests in Visual Studio .NET 2005 is 100 seconds.  If a single Cognos SDK request from C# (c-sharp) takes longer than 100 seconds then you will receive the following error:

 

            "The operation has timed out

 

            Stack trace:

                        at System.Web.Services.Protocols.WebClientProtocol.GetWebResponse(WebRequestrequest)

                        at System.Web.Services.Protocols.HttpWebClientProtocol.GetWebResponse(WebRequest request)

                        at System.Web.Services.Protocols.SoapHttpClientProtocol.Invoke(String methodName, Object[] parameters)

 

            ..."

 

 

The fix for this issue is to modify the default request timeout by setting the Timeout property of the Cognos 8 service that is being used.

 

Your sample Cognos SDK C# (c-sharp) code should be set as follows:

 

            reportService1 rptService = new reportService1();

 

            rptService.Timeout = 500000; //timeout in milliseconds

 

        // rptService.Timeout = Timeout.Infinite;  --> note:  this is not recommended for a PRODUCTION environment